By Charles Smith

The venture manager's Bible to the layout and implementation of ground-breaking buying and selling flooring to stick aggressive, buying and selling flooring require state of the art expertise, a fancy community that involves every thing from telephone strains to info servers. This useful guide deals broad, up to the moment recommendation for all these thinking about the making plans, layout and development of buying and selling flooring and knowledge facilities in any of the world's significant monetary facilities, from manhattan to Hong Kong. It covers timetables, sequential making plans lists, monetary rules, company governance and information protection. furthermore, it comprises lists of the important inquiries to ask providers, contractors and consumers. a useful reference for IT execs and senior executives within the world's best funding banks.

Show description

Read or Download Creating a Trading Floor: The Project Manager's Guide to the Design, Construction and Launch of Trading Floors and Data Centers PDF

Similar organization and data processing books

Advances in Databases and Information Systems: 12th East European Conference, ADBIS 2008, Pori, Finland, September 5-9, 2008. Proceedings

This e-book constitutes the refereed complaints of the twelfth East eu convention on Advances in Databases and data structures, ADBIS 2008, held in Pori, Finland, on September 5-9, 2008. The 22 revised papers have been rigorously reviewed and chosen from sixty six submissions. Topically, the papers span a large spectrum of the database and data platforms box: from question optimisation, and transaction processing through layout tips on how to software orientated issues like XML and information on the net.

Reconfigurable Computing: Architectures, Tools and Applications: 4th International Workshop, ARC 2008, London, UK, March 26-28, 2008. Proceedings

This ebook constitutes the refereed lawsuits of the 4th foreign Workshop on utilized Reconfigurable Computing, ARC 2008, held in London, united kingdom, in March 2008. The 21 complete papers and 14 brief papers awarded including the abstracts of three keynote lectures have been rigorously reviewed and chosen from fifty six submissions.

Data Conversion: Calculating the Monetary Benefits

This ebook tackles the 3rd significant problem and the second one so much tricky step within the ROI method: changing facts to financial values. whilst a selected undertaking or software is hooked up to a enterprise degree, the following logical query is: what's the financial worth of that influence? For ROI research, it truly is at this serious element the place the financial advantages are built to check to the prices of this system to calculate the ROI.

Additional info for Creating a Trading Floor: The Project Manager's Guide to the Design, Construction and Launch of Trading Floors and Data Centers

Sample text

It is best if they are incorporated into the planning at an early stage. RESILIENCE AND BUSINESS CONTINUITY Most trading floors have a requirement for a resilient infrastructure and business continuity facility. That requirement will vary across the different business areas in an organization. The project leader should establish, document and agree the fundamentals of the business requirement for resilience/continuity provision at an early stage. If it is not taken into account then, subsequent remedial action can be very difficult should the business decide at a later date that it is required.

Mechanical and electrical room space will be needed for electrical power protection, in the form of generator machinery, generator fuel and a UPS system. The generator will need either a fireproof room with provision for exhaust fume extraction and noise suppression, or suitable external accommodation. If the generator is housed in a building and uses liquid fuel, the surrounding floor should be tanked to contain any spilled fuel. The landlord might offer generator capacity as part of the tenancy agreement, so this is just one additional factor that needs to be checked when selecting a building for a trading floor.

Some locations are planning on heat loads of up to 25 KW per cabinet; the Chicago Mercantile Exchange has recently built a data centre using 18 KW per cabinet as an average. Office desk equipment A quick inventory should be taken of desktop equipment other than PCs and screens in use in the current environment. These might include fans, kettles, speakerphones, phone chargers and desk lighting. The total wattage of this equipment should be calculated, but it can be listed as nonessential power. Then Preparation ❙ 37 an informed guess should be taken about the likely load imposed at any one time by this equipment.

Download PDF sample